PUMP ROOM FIXED GAS SYSTEM CALIBRATION-CONSILIUM PR SYSTEM CGS50
(SG NO. 9820
PR System Calibration
1. Press Arrow > Menu
2. Select 4 Sampling Machines (1)
3. Press Arrow > Continue
4. Press Arrow > Options
5. Select Detectors (3)
6. Press Options
7. Press > Continue
8. Select 1/3 C-IC-GS-107 C3H8 1/OR 2/3 C-IC-GS-107 02 2/OR 3/3 C-IC-GS- 107 H2S 3
9. For ZERO CAL: Select 1 Calibrate Zero or For SPAN CAL: Select 2 Calibrate Span
10. Press> Continue
11. Press> Confirm
This is a guide only but useful for ETO and Officers.