ODMES-3000 ver2-KSB Seil Co., Ltd ODME OPERATIONAL TEST THROUGH SIMULATION

ODMES-3000 ver2-KSB Seil Co., Ltd

ODME OPERATIONAL TEST THROUGH SIMULATION

TEST No1-30L/NM Alarm Verification

1) Inform the Bridge OOW and Master. Call ECR to Open Air and Water on Deck

2) Open Fresh Water Supply Valve (1), Fresh Water Valve (2) to Residual Oil Tank and Air Supply Valve (3) in

the (Pump Room)

3) Check VRC normal pressure (In CCR)

4) Check ODME Power Switch (ON) the ODME system

5) Press "CONFIG

6) Select Flowmeter Point (For Manual Flow Rate in m³)

7) Press "Manual

8) Input "1000"

9) Press "OK" (If correct)

10) Select "PPM" (For PPM Set Up)

11) Select "Manual"

12) Input "290

13) Press "OK" (If correct)

14) Select "Speed" (For Manual Speed in Knots)

15) Press "Manual"

16) Input "10"

17) Press "OK" (If correct)

18) Press "SAVE"

19) Press "CONFIG"

20) Select Operating Mode (For Simulation to Open Overboard Valve and Shut Orculation Valve to Slop will shut)

21) Press "OK"

22) Press "Monitoring Mode"

23) Press "Proceed"

24) Press "OK" And wait until the overboard valve will display Open on the panel screen.

25) Press "CONFIG"

26) Select "PPM" (For PPM Set Up)

27) Select "Manual"

28) Input "310" (To verify Alarm limit and Overboard valve will close)

29) Press "OK" (If correct)

30) Select "OK" (Alarm will sound) (It Displays "ALARM" L/NM EXCEEDED)

31) Press (ALARM) displayed on the Panel Screen

32) End of Simulation Test And Reset to Normal Parameters - AUTO MODE

33) Press "CONFIG"

34) Select "PPM"

35) Select "Auto"

36) Press "OK"

37) Select "Speed"

38) Press "Auto"

39) Press "OK"

40) Select "Flowmeter Point"

41) Press "Auto"

42). Press "OK"

43) Select Operating Mode

44) Press "OK"

45) Press Standby Mode

46) Press OK

47) Press Standby Mode

48 Press SAVE

49) Press"CLOSE The Normal Panel Sreen will Display (Overboard Vavle Close Status)

50) Press DATA OUT To copy Data to USB

5) Close fresh Water Supply Valve(1), Fresh water Valve (2) to Residuaal Tank and Air Suyply Valve(3) in the Pumproom

5) Inform ECR and Bridge OOWC

NOTE:

Physical Valves Status Normally the "OD.M DischargeValve (CO 202) Close/ ODM. Return valve (CO 071) to Slop Open

Dung the Simulation Test: Manual Set Value to be Flowmeter Point 1000 /PPM: 290/ Speed: 10 kts

When set to Monitoring/Proceed, The"OD.M. Discharge Valve (C0 202) Open /OD.M Peturn Valve (CO O71) to Slop Close

To verify the Alamof more than 3O/NM ALARM" L/NM EXCEEDED) Replace the Set Value of PPM to 310

When set to Monitoring /Proceed the"O.D.M. Discharge Valve(CO 202) CLose/OD.M. Return Valve (COO71) to Slop Open

FOR DECANTING OPERATION:

53 CCR ODME PANEL-Perfom the Simulation test items No. 1-49( This is on AUTO MODE-STANDBY

54 PUMP ROOM- Open the ODME Sample Valve for( Cargo )

55) PUMP ROOM -Open the Flowmeter valves (2pcs)

56) PUMP ROOM- Close the Flowmeter bypass (1pc)

5) CCR ODME PANEL- Select sample Point-( no. 1 for Cargo)

S8) PUMP ROOM- Setup ( Using Any of the Cargo Pumps No. 1, 2, 3 or Stripping Punp) Select Tank For Decanting - (Ciculaton ROT to Slop P/ Or Slop P to Slop P/or Slop S to Slop P Or slop S to Slop S) - Start Pump

59) CCR ODME PANEL- Select"Operaing Mode"Monitoring"Proceed") (All in AUTO Mode-Ready for Decantng)-When the ODME Panel srceen shows "PERMITTED"The "OD.M. Discharge Valve (CO 202) will Open/ OD.M. Return Valve (C0 071) to Slop will close.

60) CCR hydraulic operated- Open 0DME Overboard valve (CO 072)

Note: Always refer to your specific ship manual and procedures.